Building Acoustics & SITMA Scheme Calibration

Building Acoustics Calibration

Calibration and verification of professional building acoustics measurement systems, including sound level meters and analysers, measurement microphones, acoustic calibrators, tapping machines, omnidirectional loudspeakers and complete sound-insulation test kits.

UKAS Available UK Laboratory Express Service
Calibration Capability

Building Acoustics

Building acoustics measurements depend on several pieces of equipment working accurately as a system. Campbell Associates can support the instruments used for airborne sound insulation, impact sound insulation, façade testing, room acoustics and reverberation-time measurements.

Service at a glance
UKAS Accredited calibration available
Scope Capability confirmed by instrument
Express Priority turnaround available
Most Makes Broad manufacturer and model capability
Instrument Types

What we calibrate

We calibrate a wide range of professional sound and acoustic measurement equipment, from complete sound level meters and noise dosemeters to individual microphones, preamplifiers and environmental monitoring systems. We support most leading manufacturers, including both current and legacy instruments.

Building Acoustics Sound Level Meters

Class 1 instruments and acoustic analysers configured for sound-insulation and reverberation measurements.

Complete Building Acoustics Kits

Meter, microphone, calibrator, tapping machine and source equipment assessed as a coordinated test kit.

Measurement Microphones / Mic Sets

Microphone capsules, preamplifiers and complete Mic Sets used with building-acoustics analysers.

Acoustic Calibrators

Class 1 and compatible Class 2 reference calibrators used before and after building-acoustics measurements.

Tapping Machines

Standardised five-hammer impact sources used for floor impact sound-insulation testing.

Dodecahedron / Omnidirectional Loudspeakers

Directivity verification for measurement sound sources used in airborne sound-insulation tests.

Power Amplifiers

Amplifier and source combinations used with omnidirectional loudspeakers; publish only if the lab confirms a defined verification method.

Reference Sound Sources

Calibrated/qualified acoustic sources used for comparative measurements; competitor benchmark suggests demand.

Signal Generators / Noise Sources

Integrated or standalone source generators used to excite rooms for sound-insulation and reverberation tests; verify Campbell method.

Impulse Sources / Clappers / Impact Balls

Building-acoustics accessories such as clappers and impact balls; candidate service depending on lab fixtures and method.

SITMA Calibration Package

One-stop package for SITMA members: Campbell publicly describes UKAS calibration plus tapping-machine precision measurement and loudspeaker directivity/stability evaluation.

Scope & Certification

Calibration capabilities

Hello these are our capabilities

Instrument type UKAS Traceable Standards / scope Notes
Sound level meter / analyser Yes Yes Use the sound-instrument capability wording plus any building-acoustics functions explicitly included in the approved package.
Measurement microphone / Mic Set Yes Yes Microphone sensitivity/frequency response and MicSet options as per the acoustic laboratory capability.
Acoustic calibrator Yes Yes BS EN IEC 60942 in half-inch configuration where applicable.
Tapping machine Yes Yes Service meets UKAS LAB23 requirements and includes cleaning as needed.
Dodecahedron directivity No Yes Verification of dodecahedron loudspeaker directivity to ISO 16283-1 Annex A
SITMA package Yes Yes SITMA package covering UKAS calibration, tapping-machine precision measurement and measurement-speaker directivity/stability.
Octave / third-octave filters Yes Yes
Reverberation-time functions Model dependent Model dependent
Reference sound source qualification Model dependent Model dependent
Signal generators / preamps Model dependent Model dependent
Most Makes & Models

We calibrate equipment from leading manufacturers

Can’t see your instrument? Ask our team
Larson Davis 831C; 831; SoundExpert 821ENV; legacy LxT/824 families with building-acoustics or reverberation options.
Norsonic Nor140; Nor145; Nor150; Nor277 tapping machine; Nor283 dodecahedron; Nor282/Nor280 amplifiers; Nor286 impulse source; Nor850 measurement/reporting system.
NTi Audio XL3; XL2; M2230/M2340 microphones; DS3 dodecahedron; TM EOS2 tapping machine; IB01 impact ball; Delta Clapper; PA3; Minirator MR-PRO/MR2; TalkBox.
01dB / Acoem DUO; FUSION; CUBE; TM01/MAC001 tapping machines; LS01/LS02/LS03/LS04 noise sources; CAL21/CAL31; dBInside ecosystem.
Svantek SV 977D; SV 971A; SVAN 979; SVAN 958A; SV93 tapping machine; compatible calibrators.
Brüel & Kjær / HBK 2250; 2270; current 2245/2255 where configured; Type 3207 tapping machine; B&K sound source / amplifier systems.
Rion NL-53/NL-63/NL-43 and building-acoustics accessories where supplied.
Building Acoustics Calibration calibration
Accreditation & Traceability

UKAS 0789

Our calibration service includes inspection, testing and calibration of your equipment against appropriate reference standards, with clear certification provided on completion. Where applicable, we can provide UKAS accredited or traceable calibration, with options available to help minimise equipment downtime.

  • Tapping machines
  • Sound calibrators
  • Sound level meters
  • Filters – sound level meter based octave and one third octave band filters
  • Reverberation time - one third octave band
  • Microphones
Your Calibration Service

What is included

<p>Our calibration service includes inspection, testing and calibration of your equipment against appropriate reference standards, with clear certification provided on completion. We can provide UKAS accredited or traceable calibration. </p>

  • Instrument inspection and functional checks before calibration.
  • Calibration against appropriate reference equipment and procedures.
  • Digital access to calibration certificates through the Campbell Associates certificate portal.
  • Collection and return options for mainland UK.
  • Reduced hire rates while equipment is away for calibration, subject to availability.
Simple Process

From booking to return

01
Book

Request a quote or arrange collection for your equipment.

02
Receive

Your equipment is logged, inspected and prepared for calibration.

03
Calibrate

Our technicians calibrate the instrument to the agreed service level.

04
Return

Your equipment is returned with its calibration documentation.

Campbell Associates calibration collection and laboratory service
Calibration With Campbell Associates

Calibration expertise built around your operation

Campbell Associates has provided specialist calibration services since 1999. Our UK based team combines laboratory expertise with practical support for organisations managing individual instruments, specialist measurement systems and larger equipment fleets.

  • Specialist UK laboratories

    Experienced calibration technicians working with professional sound, vibration, building acoustics and environmental measurement instrumentation.

  • Minimise equipment downtime

    Standard and express service options help keep critical measurement equipment available when you need it.

  • Fleet & contract support

    Talk to us about planned calibration programmes, multiple instruments, recurring requirements and contract pricing.

Keep your operation moving

Need equipment while yours is being calibrated?

Reduced hire rates of up to 50% may be available while your equipment is with us for calibration or repair, subject to equipment availability.

Our experienced technicians support a wide range of makes and models, helping customers maintain accurate, reliable and compliant instruments with practical turnaround and technical support.

Customers who trust Campbell Associates

Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Customers who rely on us
Questions & Answers

Frequently asked questions

Will your calibration package conform to SITMA requirements?

Yes, we worked with SITMA to ensure our calibration process met their requirements.

Calibration Enquiry

Request a calibration quote

Tell us the manufacturer, model and quantity of instruments you need calibrated. Our team can confirm capability, certification options and the next steps.