ElliTrack - Crack Monitor | Campbell Associates
ElliTrack – Crack Monitor

ElliTrack – Crack Monitor

ElliTrack - Track cracks in real-time!

Product Hire Enquiry

Have questions? Our friendly and knowledgable team are here to help.

OFFICE NUMBER:

01371 871030

Product Purchase Enquiry

Have questions? Our friendly and knowledgable team are here to help.

OFFICE NUMBER:

01371 871030

Featured product image

ElliTrack - Track cracks In Real-Time!

The Elli-Track Crack Monitor is an advanced system designed for monitoring cracks in buildings, bridges, tunnels, and other structures. It helps engineers and construction professionals track crack movement over time,...

Key Product Features

Model: ELLITRACK

SMS & Email Alerts

SMS & Email Alerts

Air Temperature Logging

Air Temperature Logging

Remote Access to Data

Remote Access to Data

Up to 3 years

Up to 3 years

Cloud Configurable

Cloud Configurable

Quick Installation

Quick Installation

Weekly Reports

Weekly Reports

1 Year Warranty

1 Year Warranty

Reliable Crack Monitoring, Anywhere

The ElliTrack crack monitoring system leverages advanced sensors, a two channel system to measure cracks in the horizontal and vertical directions, to deliver precise measurements of crack width and movement across both horizontal and vertical axes.

Its standout feature is real-time, low-power monitoring, ideal for challenging and remote locations. There low cost and sizes makes it easy to deploy multiple units in sensitive locations.

Proactive Structural Risk Management

Proactive Structural Risk Management

Monitor structural movement and potential damage with ElliTrack’s real-time data capture. Automatic data uploads to the Sonitus Cloud provide 24/7 remote access, ideal for monitoring compromised buildings or bridges impacted by nearby construction or demolition.

ElliTrack accounts for temperature fluctuations and sends instant alerts upon breach detection, empowering your team to act quickly and mitigate risks effectively.

Why Monitor Cracks?

Identify Potential Issues Before They Become Critical

While ElliTrack may have a higher upfront cost than traditional sticky gauges, it delivers significant long-term savings. Real-time data capture eliminates the need for frequent site visits, reducing labour costs and improving safety in hard-to-reach or occupied areas.

In essence, the investment in ElliTrack quickly pays off by minimising ongoing monitoring expenses and providing instant, actionable insights.

Crack & vibration monitoring at Barnes Bridge London
Identify Potential Issues Before They Become Critical

Key Product Specifications

Lightweight, 400g

Lightweight, 400g

Small but Strong

Small but Strong

Logs Air Temperature

Logs Air Temperature

6.3 um Resolution

6.3 um Resolution

Two Channels, Horizontally & Vertically

Two Channels, Horizontally & Vertically

25 mm Range (others available)

25 mm Range (others available)

IP67 Rated Logger

IP67 Rated Logger

Linearity ± 0.05 %

Linearity ± 0.05 %

Applications

Environmental Monitoring

Find out more

Demolition Projects

Find out more

Additional Accessories

Complement your product with additional items

Download Datasheet
Logger Screw & Wall Plugs: Contains 2 No. 6mm screws and 2 No. 40 mm wall plugs
Logger Screw & Wall Plugs

Logger Screw & Wall Plugs

LEI-ELLITRACK-001

Piston Sensor Screw & Wall Plugs: Contains 4 No. 6 mm x 80mm screws and 4 wall plugs and 4 zip ties.
Sensor Screw & Wall Plugs

Sensor Screw & Wall Plugs

LEI-ELLITRACK-002

Additional Piston Sensor Gauge for ElliTrack Logger
Additional Sensor Gauge

Additional Sensor Gauge

LEI-ELLITRACK-003

Refer to AVATrace for vibration monitor
Add-On a Vibration Monitor

Add-On a Vibration Monitor

AVA-M90

Need Product Support?

Our knowledgable, friendly team are here to help.

Guides & Downloads Email Support

Frequently Asked Question's

How many cracks can I monitor with the ElliTrak?

The logger has two channels, which allows measurement of up to two cracks.

What is the maximum crack width that can be measured?

The piston is designed to measure a range of 0 to 25 mm, with a mechanical range of approximately 29 mm. Therefore, the crack movement must remain within this range.

The mounting points have a wider point to point dimension. The two fixing holes are positioned approximately 150 mm apart. Installation is normally carried out by drilling two 8 mm diameter holes, approximately 40 mm deep, and using metal anchor bolts, plugs and nuts to secure the sensor.

What type of anchor fixings should be used?

Metal anchor bolts and plugs should be used. This helps ensure that expansion or contraction of the fixing does not influence the measured data.

How far off the wall does the sensor sit, and must the sensor be fixed directly to the wall?

The sensor should not be fixed directly flat against the wall, as the piston must remain free to move.

There are two supplied nuts on each bolt, allowing the engineer to position the piston a few millimetres away from the wall. This prevents the piston from touching the wall as the crack moves.

What is the cable length of the piston, and how far can it be positioned from the logger?

The maximum cable length from the piston to the logger is up to 1 metre.

If two sensors are installed on one logger, the maximum distance between measurement points could be approximately 2 metres, provided the logger is positioned centrally.

Can the crack monitor be used outdoors?

Yes. The ElliTrak crack monitor is designed for both indoor and outdoor use and has an IP67 rating. The operating temperature range is approximately minus 50 °C to 120 °C.

How long is the battery life of the crack monitor?

Battery life depends largely on the monitor settings, upload frequency and signal strength.
br> The lithium battery can provide a long battery life of up to 3 years when using daily uploads with good signal. However, where signal is poor, or where the upload period is increased, the number of possible connections is reduced.

The maximum number of connections is approximately 1,500 transmissions. This should be used to estimate the likely battery life. Transmission connections are counted on the cloud platform, so the remaining battery period can be estimated.

What type of sensor is used?

The logger uses two channels and can be connected to one or two potentiometer sensors.

What are the weight and dimensions of the equipment?

Logger Dimensions: 161 x 91 x 62 mm, H x W x D Weight: approximately 400 g, including battery

Potentiometer Extended dimensions: 143 x 25 x 18 mm, H x W x D Collapsed dimensions: 114 x 25 x 18 mm, H x W x D Weight: approximately 100 g

Do I need to consider signal strength, and where is the logger best located?

Yes, signal strength should be considered during installation.

The logger should be mounted as close to the outdoor environment as possible. Signal strength may be reduced in basements, underground areas, deep voids, or within metal lined buildings.

The sensor should always be mounted at the crack, while the logger should be positioned in as open a location as possible to obtain the best signal. Ideally, the logger should be positioned outside, or near a window.

This does not mean that the sensor cannot be used in a basement, but the installation should be assessed properly to ensure that sufficient signal strength can be achieved for remote connection and to maximise battery life.

The crack monitor logger is using more battery than expected. Why is this?

This is usually due to signal strength or the configured upload frequency.

Poor signal can increase battery consumption because the logger uses more power when attempting to connect and transmit data. More frequent transmissions will also reduce battery life.

What type of material can the crack monitor be installed on?

The crack monitor is suitable for mounting on materials such as brickwork, blockwork and concrete.

It can be used for construction, demolition, bridges, viaducts and similar structural monitoring applications.

Can the crack monitor be fixed without drilling holes in the wall?

Yes, but this would need to be done using a high strength tensile adhesive with a suitable PSI rating, so that the fixing remains rigid.

A metal plate with a threaded fixing point should be manufactured for this type of installation. This is not supplied by us.

Care should be taken when using any alternative fixing method, as some materials may influence the readings due to expansion or contraction caused by temperature or humidity.

Request a Quote

One of our experts will respond to you shortly.

Speak to our experts

Speak to our experts

CONTACT US

OFFICE NUMBER:

01371 871030

Have any questions

Our knowledgable, friendly team are here to help.

Talk to an expert

Monday to Friday, 9 AM - 5 PM

01371 871030

Get a quote

We'll get back to you quickly!

EMAIL US

Request a Call Back

Mobile, Teams or Zoom

CONTACT US